Home Page | About Us | About the products | FAQ's | Testimonials | Steam Cleaning | Steam Equipment | Distributors | Fleet Leasing | Contact Us | Order Tracking | View Cart | Checkout

Biotest

BIOTEST LABORATORIES PTY LTD

 

A.B.N. 82 010 924 571                                                                          Our Reference 153265

Unit 4, Cnr Smallwood & Darnick St.. Underwood

P.O. Box 4041 - Eight Miles Plains

Qld. 4113

Telephone (07) 3841 2232 Fax. (07) 3341 2241

14 September, 2007

 

Mr Steve hall

Green Mountain Solutions

Po Box 1065

Tweedheads NSW 2485

 

Dear Sir,

Re: CHALLENGE TEST - NATRA-KLEEN

A sample was tested as received at the laboratory on the 10th of September 2007.

This sample was analysed as directed on the 12th of September 2007 to evaluate the

performance of the product against the challenge organisms listed below.

The methodology employed followed guidelines outlined in the British Standard 3286.

The test condition and results are as follows which pertain only to the sample as tested;-

 

Sample Description     : Natra-Kleen Biotest Sample No :    7253/21

Test Conditions


Temperature            :   Ambient

Contact Period             1, 5 and 10 minutes

Recovery Media Initial Diluent - Nutrient Broth with 3% Tween 80

Product Dilution           Neat

Soil                           :   Nil

Challenge Organisms

 

Initial Challenge

Escherichia coli

ATCC 8739

2.6x106

Pseudomonas aeruginosa

ATCC 9027

1.0x107

Staphylococcus aureus

ATCC 6538

2.0x106

Salmonella typhimurium

ATCC 13311

6.2x106

Listeria monocytogenes

ACM 98

1.3x107

 

BIOTEST LABORATORIES PTY LTD                                          Our Ref.: 153265

TEST RESULTS


Challenge Organism

Recovery Count

1 minutes

Kill Factor 

5 minutes

Kill Factor %

10 minutes

Kill factor %

E.coli

2.5x106

3.84

1.2X106

53.35

1.7x106

34.62

P. aeruginosa

3.7x105

63.00

1.5X106

85.00

2.5x106

75.00

S. aureus

1.8x107

0.00

7.9x104

96.05

1.0x105

95.00

S. typhimurium

5.3x106

14.52

3.7X106

40.32

5.0x106

19.35

L monocytogenes

5.4x106

70.00

4.7X106

73.89

8.4x106

53.33


 

 

Test Organism

               Product Inactivation

Escherichia coli

Satisfactory at -1 dilution resulting in a sensitivity of <10.

Pseudomonas aeruginosa

Satisfactory at -1 dilution resulting in a sensitivity of <10.

Staphylococcus aureus

Satisfactory at -1 dilution resulting in a sensitivity of <10.

Salmonella typhimurium

Satisfactory at -1 dilution resulting in a sensitivity of <10.

Listeria monocytogenes

Satisfactory at -1 dilution resulting in a sensitivity of <10.

 

 

 

 

 

 

 

 Test Method

Biotest Method 5.2. Following guidelines in the British Standard 3286:1960. The product was tested neat.

Discussion

A Kill Factor of 99.99% or greater is regarded as evidence of significant bactericidal action. (Kill factor is defined as the ratio of the initial to final count). The product as tested did not display significant bactericidal action against any organisms tested after 10 minutes contact time.

Yours faithfully,

BIOTEST LABORATORIES PTY. LTD.,

 

FIONA MCNICOL B.App.Sc (Biotechnology)

Microbiology Manager

 


 